Page 5: Selacting Read Mode Selecting Read mode Displaying heating water temperature Displaying heating water pressure After turning the boiler on By pressing the but- with the main switch, the ton, pressure in bar in current heating water tem- the heating water system perature will appear on the will be displayed for 30 se- display. Page 6 Equithermal mode — curve slope Equithermal curves Press the button — letter E with the characters - and 1 through to 9 attached will appear on the display.
By pressing the buttons, select the re- quired equithermal curve. The pressure below boiler is automatically bar in the system. The shut down and waits for boiler is automatically the water temperature shut down — If the boiler is to remain shut down for a longer period of time, turn the gas supply Page Boiler Control Boiler control Using the boiler without a room con- Using the boiler with equithermal trol unit control When running in this mode, the boiler The boiler changes the heating water maintains the selected heating water tem- temperature as the outdoor temperature perature.
You control. For economy mode period at night, must set a temperature value this tempe- when absent , set on the room control unit rature will have no effect on the equithermal the actual required temperature — it must control mode.
Page Protection Functios Important: The single-action COMFORT ger is affected by the premises on which the function is installed on request by an au- boiler is installed chimney thrusts, room thorised service technician with the boiler temperature. Therefore we recommend to in the service mode. Page Service And Maintenance Important: All the mentioned electronic Safety valve protection functions are enabled only The boiler is equipped with a safety valve when the boiler is connected to power with an opening pressure 3 bar.
If the safety into a power socket and the main switch is valve starts releasing heating water, always II 2H3P Version. Combustion gases thermostat 8. Pump Reverse valve 1. Air manostat 9. Thrust breaker Pressure sensor Top-up valve 2. Fan Draining valve The delivery includes Fig. The boiler 2. Operatin and Installation Guide 3. Service Book 4. Page Preparing For Installation Preparing for installation Distribution pipes It is recommended to install before the bo- iler i. The sludge separator in the usual way, using the pump charac- should be constructed in such a way that teristic.
Page Installing The Boiler Thermostatic radiators valves Hot water system If a room control unit is installed, at least Pressure inside the hot water system must one of the radiators in the reference room be within the range of 1 to 6 bar. If the pres- must be without a thermostatic valve.
Page 26 Mouting the boiler Fig. Page 30 are terminated in the chimney from opposi- Method C te directions, the minimum vertical distance between them must be 0. Both route sections the outside — Page 32 Permissible exhaust outlet locations Fig. Page Electrical Wiring constitute no obstacle and are open , Safety measures such as tunnels, subways, etc.
This manual is also suitable for: Panther 24 kov Panther 28 ktv. Print page 1 Print document 37 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Wall-hang non-condensing boiler power 8,5 - 23,3 kw flow heating hw 41 pages. The control panel is accessible after removing the front cover. Page 4: Introduction Introduction 1.
The boiler and all the associated have this performed by a professional equipment must be installed and used technician who shall install the boiler or in accordance with the installation put it into operation. Heating water pressure LED — indicates used to switch the boiler on or off. The that pressure is being displayed main switch is situated in the lower half of 5. If the temperature of the heating water Page Service And Maintenance Pump protection Power failure Switching the pump on for a short time Power failure will turn the boiler off.
When approx. II 2H3P Version. Combustion gases thermostat 7. Pump Gas inlet 1. Air manostat 8. Safety valve Thrust breaker 9. Case for 3-way valve Heating water pressure sensor 2. Combustion gases thermostat 9. Heating water outlet 1. Air manostat Hot water heat exchanger Thrust breaker Draining valve Page 24 mm on all sides and min.
In the 24 KTV and 24 12 KTO models, combustion gases must be always remo- ved and fresh air supplied through dual ducting specially designed for this purpo- se. Page 26 Content of boiler delivery List of service centres Template Page Preparing For Boiler Installation Preparing for boiler installation Distribution pipes of radiator manufacturers.
It is recommended to install upstream Nominal pipe internal diameter is chosen the boiler i. The sludge teristic. Page 28 Hot water system side, combined with a safety valve. Pressure inside the hot water system must be within the range of 1 to 6 bar. Mount isolation valves on all outlets from the boiler not part of delivery. When mounting the boiler on the wall, pro-